Filters
Close

Tripp Lite 3-Phase PDU Monitored 14.5kW 208/240V 30 C13; 12 C19 Hubbell TAA

Tripp Lite 3-Phase PDU Monitored 14.5kW 208/240V 30 C13; 12 C19 Hubbell TAA - Monitored - Hubbell CS8365C - 12 x IEC 60320 C19, 30 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA Compliant
SKU: 1000279899
Manufacturer part number: PDU3EVN6H50BA
Free shipping
Manufacturer: Tripp Lite
Old price: $1,959.98
$1,233.58
Picture of Tripp Lite 3-Phase PDU Monitored 14.5kW 208/240V 30 C13; 12 C19 Hubbell TAA
Features

14.5kW 3-Phase PDU Distributes and Monitors Network-Grade Power

This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for data centers, server rooms and high-density network closets, the PDU3EVN6H50BA features 30 C13 and 12 C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.

Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The monitored PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rackmounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with Hubbell CS8365C 208/240V 3-phase input connects the PDU to a compatible AC power source, generator or protected UPS.

Product Information

Transource eSKU1053343060
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberPDU3EVN6H50BA
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product ModelPDU3EVN6H50BA
Product NamePDU3EVN6H50BA 42-Outlet PDU
Product TypePDU

Specifications

Technical Information
PDU TypeMonitored
PhaseThree Phase
Plug/Connector TypeHubbell CS8365C
Receptacle TypeIEC 60320 C19
Receptacle TypeIEC 60320 C13
Receptacle Detail12 x IEC 60320 C19
Receptacle Detail30 x IEC 60320 C13
Protection TypeOverload Protection
Power Description
Input Voltage230 V AC
Output Voltage208 V AC
Output Voltage240 V AC
Power Rating (Watt)14.50 kW
Input Current35 A
Management
ManagementProtocols:
  • IPv4
  • IPv6
  • HTTP
  • HTTPS
  • SMTP
  • SNMPv1
  • SNMPv2
  • SNMPv3
  • telnet
  • SSH
  • FTP
  • DHCP
  • NTP
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mounting OrientationVertical
Mount TypeRack-mountable
Rack Height0U
Height70"
Width2.2"
Depth2.5"
Weight (Approximate)12.85 lb
Miscellaneous
Package Contents
  • PDU3EVN6H50BA 42-Outlet PDU
  • Built-in LX Platform Interface
  • Configuration Cable
  • 42 x Plug-lock Insert Sleeves
  • Rack-Mounting Hardware
  • Spare Mounting Buttons
  • Mounting Bracket Accessory
  • Owner's Manual
Environmentally FriendlyYes
Environmental CertificationRoHS
Country of OriginTaiwan
TAA CompliantYes
Warranty
Limited Warranty2 Year
Features

14.5kW 3-Phase PDU Distributes and Monitors Network-Grade Power

This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for data centers, server rooms and high-density network closets, the PDU3EVN6H50BA features 30 C13 and 12 C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.

Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The monitored PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rackmounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with Hubbell CS8365C 208/240V 3-phase input connects the PDU to a compatible AC power source, generator or protected UPS.

Product Information

Transource eSKU1053343060
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberPDU3EVN6H50BA
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product ModelPDU3EVN6H50BA
Product NamePDU3EVN6H50BA 42-Outlet PDU
Product TypePDU

Specifications

Technical Information
PDU TypeMonitored
PhaseThree Phase
Plug/Connector TypeHubbell CS8365C
Receptacle TypeIEC 60320 C19
Receptacle TypeIEC 60320 C13
Receptacle Detail12 x IEC 60320 C19
Receptacle Detail30 x IEC 60320 C13
Protection TypeOverload Protection
Power Description
Input Voltage230 V AC
Output Voltage208 V AC
Output Voltage240 V AC
Power Rating (Watt)14.50 kW
Input Current35 A
Management
ManagementProtocols:
  • IPv4
  • IPv6
  • HTTP
  • HTTPS
  • SMTP
  • SNMPv1
  • SNMPv2
  • SNMPv3
  • telnet
  • SSH
  • FTP
  • DHCP
  • NTP
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mounting OrientationVertical
Mount TypeRack-mountable
Rack Height0U
Height70"
Width2.2"
Depth2.5"
Weight (Approximate)12.85 lb
Miscellaneous
Package Contents
  • PDU3EVN6H50BA 42-Outlet PDU
  • Built-in LX Platform Interface
  • Configuration Cable
  • 42 x Plug-lock Insert Sleeves
  • Rack-Mounting Hardware
  • Spare Mounting Buttons
  • Mounting Bracket Accessory
  • Owner's Manual
Environmentally FriendlyYes