Filters
Close

Tripp Lite Isolation Transformer Hospital Dual-Voltage 115/230V 300W 4 C13

Tripp Lite Isolation Transformer Hospital Dual-Voltage 115/230V 300W 4 C13 - 300 VA - 120 V AC, 230 V AC Input - 115 V AC, 230 V AC Output
SKU: 1000191743
Manufacturer part number: IS300HGDV
Free shipping
Manufacturer: Tripp Lite
Old price: $1,077.44
$678.12
Picture of Tripp Lite Isolation Transformer Hospital Dual-Voltage 115/230V 300W 4 C13
The IS300HGDV Isolator® Series Dual-Voltage 115/230V 300W 50/60Hz Medical-Grade™ Transformer with full CAN/ES/IEC/EN 60601-1 listing is ideal for protecting sensitive electronic equipment in patient-care vicinities. It can be configured for either step-up voltage, step-down voltage or pass-through voltage operation. Along with line isolation and continuous EMI/RFI line noise filtering, its surge protection rating of 240 joules suppresses excess voltage to prevent it from damaging connected equipment.

An internal low-impedance isolation transformer component offers 100% isolation from the input mains AC line. Faraday shield reduces the cumulative leakage current of the IS300HGDV and connected equipment to levels less than 50 microamps, while removing utility switching transients and harmonics generated by other on-site loads and reducing the impact of utility or lightning related surge conditions.

Transformer filtering provides continuous common-mode noise rejection with no wearable parts. The IS300HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.

Components connect to four C13 outlets with fuse overload protection and a lighted on/off switch. The rugged all-metal unit housing ships ready for placement in any industrial, medical, office, network or audio/video environment. Requires a C14-to-C13 AC input cord (sold separately).

Product Information

Transource eSKU1045664016
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberIS300HGDV
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product LineIsolator
Product ModelIS300HGDV
Product NameIsolator IS300HGDV Isolation Transformer
Product TypeIsolation Transformer

Product Specifications

General Information
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberIS300HGDV
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product LineIsolator
Product ModelIS300HGDV
Product NameIsolator IS300HGDV Isolation Transformer
Marketing InformationThe IS300HGDV Isolator® Series Dual-Voltage 115/230V 300W 50/60Hz Medical-Grade™ Transformer with full CAN/ES/IEC/EN 60601-1 listing is ideal for protecting sensitive electronic equipment in patient-care vicinities. It can be configured for either step-up voltage, step-down voltage or pass-through voltage operation. Along with line isolation and continuous EMI/RFI line noise filtering, its surge protection rating of 240 joules suppresses excess voltage to prevent it from damaging connected equipment.

An internal low-impedance isolation transformer component offers 100% isolation from the input mains AC line. Faraday shield reduces the cumulative leakage current of the IS300HGDV and connected equipment to levels less than 50 microamps, while removing utility switching transients and harmonics generated by other on-site loads and reducing the impact of utility or lightning related surge conditions.

Transformer filtering provides continuous common-mode noise rejection with no wearable parts. The IS300HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.

Components connect to four C13 outlets with fuse overload protection and a lighted on/off switch. The rugged all-metal unit housing ships ready for placement in any industrial, medical, office, network or audio/video environment. Requires a C14-to-C13 AC input cord (sold separately).
Product TypeIsolation Transformer
Technical Information
Power Rating300 VA
Input Receptacle TypeIEC 60320 C14
Output Receptacle TypeIEC 60320 C13
Power Description
Input Voltage120 V AC
Input Voltage230 V AC
Output Voltage115 V AC
Output Voltage230 V AC
Maximum Line Current3.15 A
Physical Characteristics
Height4.3"
Width5.5"
Depth7.9"
Form FactorCabinet
Weight (Approximate)12.35 lb
Miscellaneous
Package Contents
  • Isolator IS300HGDV Isolation Transformer
  • 2 x Fuse Sets (115V and 230V Operation)
  • Input/Output Cable Selector Data Sheet
  • Owner's Manual
Environmentally FriendlyYes
Environmental CertificationRoHS
Country of OriginChina
Warranty
Limited Warranty2 Year
The IS300HGDV Isolator® Series Dual-Voltage 115/230V 300W 50/60Hz Medical-Grade™ Transformer with full CAN/ES/IEC/EN 60601-1 listing is ideal for protecting sensitive electronic equipment in patient-care vicinities. It can be configured for either step-up voltage, step-down voltage or pass-through voltage operation. Along with line isolation and continuous EMI/RFI line noise filtering, its surge protection rating of 240 joules suppresses excess voltage to prevent it from damaging connected equipment.

An internal low-impedance isolation transformer component offers 100% isolation from the input mains AC line. Faraday shield reduces the cumulative leakage current of the IS300HGDV and connected equipment to levels less than 50 microamps, while removing utility switching transients and harmonics generated by other on-site loads and reducing the impact of utility or lightning related surge conditions.

Transformer filtering provides continuous common-mode noise rejection with no wearable parts. The IS300HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.

Components connect to four C13 outlets with fuse overload protection and a lighted on/off switch. The rugged all-metal unit housing ships ready for placement in any industrial, medical, office, network or audio/video environment. Requires a C14-to-C13 AC input cord (sold separately).

Product Information

Transource eSKU1045664016
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberIS300HGDV
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product LineIsolator
Product ModelIS300HGDV
Product NameIsolator IS300HGDV Isolation Transformer
Product TypeIsolation Transformer

Product Specifications

General Information
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberIS300HGDV
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product LineIsolator
Product ModelIS300HGDV
Product NameIsolator IS300HGDV Isolation Transformer
Marketing InformationThe IS300HGDV Isolator® Series Dual-Voltage 115/230V 300W 50/60Hz Medical-Grade™ Transformer with full CAN/ES/IEC/EN 60601-1 listing is ideal for protecting sensitive electronic equipment in patient-care vicinities. It can be configured for either step-up voltage, step-down voltage or pass-through voltage operation. Along with line isolation and continuous EMI/RFI line noise filtering, its surge protection rating of 240 joules suppresses excess voltage to prevent it from damaging connected equipment.

An internal low-impedance isolation transformer component offers 100% isolation from the input mains AC line. Faraday shield reduces the cumulative leakage current of the IS300HGDV and connected equipment to levels less than 50 microamps, while removing utility switching transients and harmonics generated by other on-site loads and reducing the impact of utility or lightning related surge conditions.

Transformer filtering provides continuous common-mode noise rejection with no wearable parts. The IS300HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.

Components connect to four C13 outlets with fuse overload protection and a lighted on/off switch. The rugged all-metal unit housing ships ready for placement in any industrial, medical, office, network or audio/video environment. Requires a C14-to-C13 AC input cord (sold separately).
Product TypeIsolation Transformer
Technical Information
Power Rating300 VA
Input Receptacle TypeIEC 60320 C14
Output Receptacle TypeIEC 60320 C13
Power Description
Input Voltage120 V AC
Input Voltage230 V AC
Output Voltage115 V AC
Output Voltage230 V AC
Maximum Line Current3.15 A
Physical Characteristics
Height4.3"
Width5.5"
Depth7.9"
Form FactorCabinet
Weight (Approximate)12.35 lb
Miscellaneous
Package Contents
  • Isolator IS300HGDV Isolation Transformer
  • 2 x Fuse Sets (115V and 230V Operation)
  • Input/Output Cable Selector Data Sheet
  • Owner's Manual
Environmentally FriendlyYes
Environmental CertificationRoHS
Country of OriginChina
Warranty
Limited Warranty2 Year
Categories