Filters
Close

Tripp Lite UPS Smart Online 2200VA 1800W Rackmount 120V LCD USB DB9 2URM

Tripp Lite UPS Smart Online 2200VA 1800W Rackmount 120V LCD USB DB9 2URM - 2U Rack/Tower - 4 Minute Stand-by - 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Input - 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Output
SKU: 1000358023
Manufacturer part number: SU2200RTXLCD2U
Free shipping
Manufacturer: Tripp Lite
Old price: $2,791.16
$1,569.87
Picture of Tripp Lite UPS Smart Online 2200VA 1800W Rackmount 120V LCD USB DB9 2URM
2kVA 1.8kW 120V Battery Backup Protects Equipment against Damage, Downtime and Data Loss
This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SU2200RTXLCD2U provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP72RT, sold separately).

Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

NEMA Outlets Protect Your Connected Components
One L5-20R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split evenly into two switchable load banks that let you reboot select components or shed non-critical loads to extend runtime for critical loads. A cooling fan helps protect equipment from overheating.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
The two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery or bypass mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.

Automatically Turns Back On After Power Is Restored
Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even after a complete battery discharge.

More from the Manufacturer

Product Information

Transource eSKU 1000358023
Manufacturer Tripp Lite by Eaton
Manufacturer Part Number SU2200RTXLCD2U
Manufacturer Website Address https://tripplite.eaton.com/
Brand Name Tripp Lite series
Product Line SmartOnline
Product Model SU2200RTXLCD2U
Product Name SmartOnline SU2200RTXLCD2U 2000VA Rack/Tower UPS
Product Type Double Conversion Online UPS

Technical Specifications

Technical Information

Plug/Connector Type NEMA 5-15P
Receptacle Type NEMA 5-20R
Receptacle Type NEMA L5-20R
Receptacle Detail 6 x NEMA 5-20R
Receptacle Detail 1 x NEMA L5-20R
Overload Protection Yes
Transfer Time 0 ns
EMI/RFI Noise Filter Yes
Phase Single Phase
Energy Saving High efficiency economy mode operation; Individually controllable load banks
Application/Usage Education
Application/Usage Healthcare
Application/Usage Military
Application/Usage Government
Application/Usage IT Equipment
Application/Usage Mission Critical Equipment

Power Description

Load Capacity (VA) 2000 VA
Load Capacity (Watt) 1800 W
Input Voltage 120 V AC
Output Voltage 100 V AC
Output Voltage 110 V AC
Output Voltage 115 V AC
Output Voltage 120 V AC
Output Voltage 127 V AC
Input Frequency 60 Hz
Output Frequency 60 Hz
Waveform Type Pure Sine Wave
Surge Energy Rating 190 J
Input Power Factor 0.99
Output Power Factor 0.9

Display & Graphics

Display LCD

Management

Network Management SNMP
Alarm Remote Shutdown
Alarm UPS StartUp
Alarm Power Failure
Alarm Overload
Alarm UPS Fault
Alarm Low Battery

Controls/Indicators

Status Indicators 4 x status-indicating LEDs

Interfaces/Ports

Serial Port Yes
USB Yes

Battery Information

DC System Voltage 72 V DC
Battery Characteristics Valve-regulated
Battery Chemistry Lead Acid
Backup/Run Time (Full Load) 7.70 Minute
Backup/Run Time (Half Load) 20.20 Minute
Typical Battery Recharge Time 3 Hour
Hot Swappable Yes
Replaceable Battery Yes

Environmental Conditions

Minimum Operating Temperature 32°F (0°C)
Maximum Operating Temperature 104°F (40°C)
Storage Temperature 32°F (0°C) - 104°F (40°C)
Maximum Operating Elevation 9842.52 ft
Sound Emission 47 dB

Physical Characteristics

Height 3.4"
Width 17.3"
Depth 23.8"
Rack Height 2U
Form Factor Rack/Tower
Weight (Approximate) 61.51 lb

Miscellaneous

Package Contents
  • SmartOnline SU2200RTXLCD2U 2000VA Rack/Tower UPS
  • USB Cable
  • DB9 RS232 Cable
  • Rack-mounting Hardware
  • Tower Support Stands
  • Safety Instructions
  • Quick Start Guide
  • Software Included PowerAlert UPS Monitoring Software
    Energy Star Yes
    Country of Origin China
    Environmentally Friendly Yes
    Environmental Compliance Registration, Evaluation, Authorization and Restriction of Chemicals (REACH)
    Environmental Compliance Restriction of Hazardous Substances (RoHS)

    Warranty

    Limited Warranty 2 Year
    2kVA 1.8kW 120V Battery Backup Protects Equipment against Damage, Downtime and Data Loss
    This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SU2200RTXLCD2U provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

    Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
    The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP72RT, sold separately).

    Optional LX Platform Network Management Card Allows Remote Access 24/7
    The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

    NEMA Outlets Protect Your Connected Components
    One L5-20R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split evenly into two switchable load banks that let you reboot select components or shed non-critical loads to extend runtime for critical loads. A cooling fan helps protect equipment from overheating.

    Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
    This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

    Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
    The two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery or bypass mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.

    Automatically Turns Back On After Power Is Restored
    Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even after a complete battery discharge.

    More from the Manufacturer

    Product Information

    Transource eSKU 1000358023
    Manufacturer Tripp Lite by Eaton
    Manufacturer Part Number SU2200RTXLCD2U
    Manufacturer Website Address https://tripplite.eaton.com/
    Brand Name Tripp Lite series
    Product Line SmartOnline
    Product Model SU2200RTXLCD2U
    Product Name SmartOnline SU2200RTXLCD2U 2000VA Rack/Tower UPS
    Product Type Double Conversion Online UPS

    Technical Specifications

    Technical Information

    Plug/Connector Type NEMA 5-15P
    Receptacle Type NEMA 5-20R
    Receptacle Type NEMA L5-20R
    Receptacle Detail 6 x NEMA 5-20R
    Receptacle Detail 1 x NEMA L5-20R
    Overload Protection Yes
    Transfer Time 0 ns
    EMI/RFI Noise Filter Yes
    Phase Single Phase
    Energy Saving High efficiency economy mode operation; Individually controllable load banks
    Application/Usage Education
    Application/Usage Healthcare
    Application/Usage Military
    Application/Usage Government
    Application/Usage IT Equipment
    Application/Usage Mission Critical Equipment

    Power Description

    Load Capacity (VA) 2000 VA
    Load Capacity (Watt) 1800 W
    Input Voltage 120 V AC
    Output Voltage 100 V AC
    Output Voltage 110 V AC
    Output Voltage 115 V AC
    Output Voltage 120 V AC
    Output Voltage 127 V AC
    Input Frequency 60 Hz
    Output Frequency 60 Hz
    Waveform Type Pure Sine Wave
    Surge Energy Rating 190 J
    Input Power Factor 0.99
    Output Power Factor 0.9

    Display & Graphics

    Display LCD

    Management

    Network Management SNMP
    Alarm Remote Shutdown
    Alarm UPS StartUp
    Alarm Power Failure
    Alarm Overload
    Alarm UPS Fault
    Alarm Low Battery

    Controls/Indicators

    Status Indicators 4 x status-indicating LEDs

    Interfaces/Ports

    Serial Port Yes
    USB Yes

    Battery Information

    DC System Voltage 72 V DC
    Battery Characteristics Valve-regulated
    Battery Chemistry Lead Acid
    Backup/Run Time (Full Load) 7.70 Minute
    Backup/Run Time (Half Load) 20.20 Minute
    Typical Battery Recharge Time 3 Hour
    Hot Swappable Yes
    Replaceable Battery Yes

    Environmental Conditions

    Minimum Operating Temperature 32°F (0°C)
    Maximum Operating Temperature 104°F (40°C)
    Storage Temperature 32°F (0°C) - 104°F (40°C)
    Maximum Operating Elevation 9842.52 ft
    Sound Emission 47 dB

    Physical Characteristics

    Height 3.4"
    Width 17.3"
    Depth 23.8"
    Rack Height 2U
    Form Factor Rack/Tower
    Weight (Approximate) 61.51 lb

    Miscellaneous

    Package Contents
  • SmartOnline SU2200RTXLCD2U 2000VA Rack/Tower UPS
  • USB Cable
  • DB9 RS232 Cable
  • Rack-mounting Hardware
  • Tower Support Stands
  • Safety Instructions
  • Quick Start Guide
  • Software Included PowerAlert UPS Monitoring Software
    Energy Star Yes
    Country of Origin China
    Environmentally Friendly Yes
    Environmental Compliance Registration, Evaluation, Authorization and Restriction of Chemicals (REACH)
    Environmental Compliance Restriction of Hazardous Substances (RoHS)

    Warranty

    Limited Warranty 2 Year
    Categories